| Certification and testing procedures
The Loss Prevention Standard LPS 1175 testing procedures for these products can be downloaded here.
|
| To view which tools were used to test each security level, please select a tool category: |
|
|
|
|
|
|
|
Level 4 - Tool Category D
|
|
|
|
|
Level 3 - Tool Category C
|
|
|
|
|
Level 2 - Tool Category B
|
|
|
|
|
|
|
|
Level 4 - TOOL CATEGORY D
|
|
|
ExcluDoor 4 doors have been proven to be capable of withstanding experienced attempts at forced entry using a selection of power tools over a maximum test period of 30 minutes regardless of noise (see opposite).
|
|
Tool category A, B and C plus:
1 “A-tool” lock puller - 500 mm long
1 Bolt cutters - 500 mm long
1 Disc grinder (cordless)* - 12V d.c with 3 cutting discs
1 Drill (cordless with rotary action only) - 12V d.c*
5 Drill bits (13 mm diameter jobber - HSS/HSCO/Carbide)
1 Felling/fire axe - 850 mm long/3 kg
1 General purpose saw
1 Hole saw - 50 mm diameter
1 Hooligan bar - 760 mm long
1 Jigsaw (cordless) - 12V d.c with 3 HSS/HSCO/ Carbide blades*
1 “K-tool” lock remover
1 Plate shears - 300 mm long
1 Sledgehammer - 750 mm long/3 kg
Steel wedges - 150 mm long
1 Tube - 75 mm diameter x 500 mm long |
|
| * Complete with a spare power pack. |
|
| Note: This tool category is for experienced attempts at forced entry. |
|
|
|
|
|
|
| Level 3 - TOOL CATEGORY C |
|
|
ExcluDoor 3 doors withstood attack for a maximum test duration of 20 minutes against a selection of hand and battery operated power tools (see opposite).
|
|
Tool category A and B plus:
1 Axe - 350 mm long/1.5 kg
Brick bolsters - 250 mm long x 75 mm wide blade
Cold chisels - 250 mm long x 25 mm wide blade
1 Crowbar - 700 mm long/2.5 kg
1 Drill (cordless with rotary action only) - 7.2V d.c*
1 Drill bit (10 mm diameter jobber - HSS/HSCO/Carbide)
1 Gas torch (Butane / Propane)
1 Hacksaw plus 2 HSS blades
1 Hammer - 400 mm long/1.5 kg
1 Pad saw plus 2 HSS blades
1 Scissor jack 750 kg capacity, 100 mm minimum retracted, 200 mm stroke
Wood chisels - 250 mm long x 25 mm wide blade |
|
| * Complete with a spare power pack. |
|
| Note: The tool category is for deliberate forced entry of well-protected premises using bodily physical force and a wide selection of attack options. |
|
|
|
|
|
|
| Level 2 - TOOL CATEGORY B |
|
|
|
|
SR2 doors withstood attack for a maximum test duration of 15 minutes against a selection of hand and battery operated power tools (see opposite).
|
|
Tool category A plus:
1 Bolt cutter - 350 mm long
1 Claw hammer - 350 mm long/0.7kg
1 Drill bit (6 mm diameter jobber - HSS / HSCO / Carbide)
1 Hand drill - 400 mm long/1.5kg
1 Junior hacksaw plus 2 HSS blades
1 Metal plate shears - 200 mm long
1 Multiple slip joint pliers - 250 mm long
1 Pipe wrench - 250 mm long
Pliers (including self gripping) - selection 250 mm long
1 Screwdriver - 7 mm diameter/square x 250 mm long
1 Screwdriver - 14 mm diameter/square x 400 mm long
1 Tube - 38 mm diameter x 300 mm long
|
|
| Note: This tool category provides a more determined opportunist attack by bodily physical force and tools with a higher mechanical advantage. |
|
|
|
|
|
|
| For description of Tool Catgories A and B please refer to the LPS 1175 testing procedures document. |
|
|
|
|
|
|
|
| Excludoor LPS1175 level 3 and level 4 steel security doors are suitable for high risk situations. |
|
|